Turning
Automatic Ultrasonic Data into FFS Data |
Time: |
Room C |
|
Michael Sens, Mechanical Integrity Using automated Ultrasonic scanning systems,
vessels and piping can be inspected and the data utilized for Fitness for
Service Calculations. The ability of
this system to create images that explicitly detail areas of wall loss allows
individuals with no ultrasonic understanding to see where in the piece of
equipment defects are located. This
paper discusses the practical application of turning these images into
substantial data that Engineers can utilize to make Fitness for Service
Calculations. |
||